LAMINAR FLOW CABINET (CFL)

Albian “CFL PN” vertical laminar flow cabinets provide the highest operator protection level, using HEPA filtering to minimise the risk of cross contamination with other products or processes.

Robust construction and greater reliability make them suitable for a long life of use in the applicable sectors.

They provide a large space for angering many types and sizes of containers such as sacks, drums, intermediate containers and others and the possibility of integrating additional process equipment such as mixers, loading hoppers, etc.

CHARACTERISTICS

 AISI 304 stainless steel sheet.
Divided furniture to facilitate assembly.

Perforated stainless steel sheet.

PVC, antistatic, vertical.

Perforated grille placed in the cabinet return; G4, F9 or H13 pre-filter options.

Prior filtering: G-4 filters (90-95% gravimetric).

Final filtering: H-14 filters (99.995% MPPS E).

Maintenance: filter replacement from the working area.

 

 

LED,

Intensity > 600 lux.

 

Double pressure gauge with differential reading; filter blocking control.

Electrical protection elements. Filter blocking alarm, hot wire speed probe.

220VA C/50Hz.

Touchscreen and easily used GUI, electrical connections, voice and data.

Adjustable from 0.45 m/s ± 20%.

About 10% by the cabinet front to generate a negative gradient inside.

High efficiency EC fans with low noise level and adjustable speed.

IQ /OQ qualification documentation.

IQ /OQ qualification execution.

Construction for various voltages.

Air curtain instead of PVC slats.

Stainless steel work table with perforated sheet to favour air passage.

Cooling system.

  • Cooling system consisting of a direct expansion bank or installation cold water (7/12 °C).

F9 filtering in return.

  • Air filter used in general ventilation to eliminate particles. F9 effectiveness grades.

H14 filtering in BI/BO return.

  • Air filter used in general ventilation to eliminate particles. H14 effectiveness grades.
  • Bag-in/bag-out (BIBO) for changing filters with containment.

 

Monitoring packet 1

  • Controller and recorder certifiable as per CFR21 Part 11 with Ethernet communication.

Monitoring packet 2

  • Particles counting.
  • Controller and recorder certifiable as per CFR21 Part 11 with Ethernet communication.
  • Filters pressure probe.
  • One 0.5 μm and 5 μm particles counter.
  • LCD display screen.

Models and Dimensions

MODEL TYPE EXTERNAL DIMENSIONS (mm.)
WIDTH HEIGHT DEPTH WIDTH HEIGHT DEPTH
CFL – PN – 1,2 x 1,2 1.400 1.400 2.100 1.400 2.100 2.800
CFL – PN – 1,2 x 1,8 2.100 1.400 2.100 2.100 2.100 2.800
CFL – PN – 1,8 x 1,8 2.100 2.100 2.100 2.100 2.800 2.800
CFL – PN – 1,8 x 2,4 2.800 2.100 2.100 2.800 2.800 2.800
CFL – PN – 2,4 x 2,4 2.800 2.800 2.100 2.800 3.500 2.800